Review measurement

2026-09-27 23:28

Drift Merlin M (2023)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

c1
nom:
7440
rdg:
7431
diff:
 -9
c2
nom:
7390
rdg:
7378
diff:
-12
c3
nom:
7359
rdg:
7344
diff:
-15
c4
nom:
7379
rdg:
7363
diff:
-16
d1
nom:
7527
rdg:
7511
diff:
-16
d2
nom:
7479
rdg:
7461
diff:
-18
d3
nom:
7443
rdg:
7425
diff:
-18
d4
nom:
7458
rdg:
7441
diff:
-17

Right riser

c1
nom:
7440
rdg:
7433
diff:
 -7
c2
nom:
7390
rdg:
7380
diff:
-10
c3
nom:
7359
rdg:
7344
diff:
-15
c4
nom:
7379
rdg:
7365
diff:
-14
d1
nom:
7527
rdg:
7513
diff:
-14
d2
nom:
7479
rdg:
7462
diff:
-17
d3
nom:
7443
rdg:
7426
diff:
-17
d4
nom:
7458
rdg:
7440
diff:
-18

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

Right riser

nom:
7323.00
rdg:
7299.00
diff:
-24.00
nom:
7338.38
rdg:
7326.50
diff:
-11.88

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (-18) of the deviations of all measurements from their nominal values.

No issues were found