Review measurement

2025-11-30 09:07

Nova Mentor 3 Light XXS (2013)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A8R
nom:
6071
rdg:
6065
diff:
 -6
A9R
nom:
5997
rdg:
5989
diff:
 -8
S1R
nom:
5845
rdg:
5835
diff:
-10
B8R
nom:
6054
rdg:
6052
diff:
 -2
B9R
nom:
5998
rdg:
5992
diff:
 -6
S2R
nom:
5881
rdg:
5873
diff:
 -8
S3R
nom:
5937
rdg:
5923
diff:
-14
S4R
nom:
6002
rdg:
5989
diff:
-13

Right riser

A8R
nom:
6071
rdg:
6066
diff:
 -5
A9R
nom:
5997
rdg:
5987
diff:
-10
S1R
nom:
5845
rdg:
5829
diff:
-16
B8R
nom:
6054
rdg:
6048
diff:
 -6
B9R
nom:
5998
rdg:
5987
diff:
-11
S2R
nom:
5881
rdg:
5869
diff:
-12
S3R
nom:
5937
rdg:
5921
diff:
-16
S4R
nom:
6002
rdg:
5986
diff:
-16

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found