Review measurement

2024-11-05 16:16

AirDesign Volt 5 M (2024)

Accuracy

Is calculated by comparing each suspension point's length change to the main line's overall change after re-measurement. Deviations over 3.0mm from the average are considered noticeable and may distort the trim result.

Left riser

avg change:
6.13
std dev:
1.55
A1a
dev:
-0.9
A2a
dev:
-1.9
A3a
dev:
-1.9
A4a
dev:
-0.9
A1b
dev:
+1.1
A2b
dev:
+1.1
A3b
dev:
+2.1
A4b
dev:
+1.1
avg change:
5.75
std dev:
1.39
B5
dev:
-1.3
B6
dev:
+0.8
B7
dev:
-0.3
B8
dev:
+1.8
C9
dev:
-2.3
C10
dev:
-0.3
C11
dev:
+1.8
C12
dev:
-0.3

Right riser

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A13
nom:
7065
rdg:
7059
diff:
 -6
A14
nom:
6952
rdg:
6950
diff:
 -2
A15
nom:
6932
rdg:
6933
diff:
 +1
B13
nom:
7023
rdg:
7017
diff:
 -6
B14
nom:
6950
rdg:
6947
diff:
 -3
B15
nom:
6940
rdg:
6936
diff:
 -4
C13
nom:
6978
rdg:
6971
diff:
 -7
C14
nom:
7001
rdg:
6989
diff:
-12

Right riser

A13
nom:
7065
rdg:
7053
diff:
-12
A14
nom:
6952
rdg:
6948
diff:
 -4
A15
nom:
6932
rdg:
6932
diff:
 +0
B13
nom:
7023
rdg:
7016
diff:
 -7
B14
nom:
6950
rdg:
6942
diff:
 -8
B15
nom:
6940
rdg:
6936
diff:
 -4
C13
nom:
6978
rdg:
6971
diff:
 -7
C14
nom:
7001
rdg:
6993
diff:
 -8

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found

Buy us coffee