Review measurement

2025-12-20 19:17

Ozone Enzo 3 M (2017)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

B1
nom:
8311
rdg:
8307
diff:
 -4
B2
nom:
8261
rdg:
8265
diff:
 +4
B3
nom:
8166
rdg:
8167
diff:
 +1
B4
nom:
8162
rdg:
8165
diff:
 +3
B5
nom:
8137
rdg:
8135
diff:
 -2
B6
nom:
8128
rdg:
8131
diff:
 +3
B7
nom:
8168
rdg:
8164
diff:
 -4
B8
nom:
8195
rdg:
8190
diff:
 -5
C1
nom:
8430
rdg:
8432
diff:
 +2
C2
nom:
8382
rdg:
8383
diff:
 +1
C3
nom:
8290
rdg:
8289
diff:
 -1
C4
nom:
8284
rdg:
8283
diff:
 -1

Right riser

B1
nom:
8311
rdg:
8305
diff:
 -6
B2
nom:
8261
rdg:
8257
diff:
 -4
B3
nom:
8166
rdg:
8159
diff:
 -7
B4
nom:
8162
rdg:
8157
diff:
 -5
B5
nom:
8137
rdg:
8134
diff:
 -3
B6
nom:
8128
rdg:
8128
diff:
 +0
B7
nom:
8168
rdg:
8161
diff:
 -7
B8
nom:
8195
rdg:
8190
diff:
 -5
C1
nom:
8430
rdg:
8419
diff:
-11
C2
nom:
8382
rdg:
8372
diff:
-10
C3
nom:
8290
rdg:
8288
diff:
 -2
C4
nom:
8284
rdg:
8278
diff:
 -6

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

Right riser

nom:
7952.75
rdg:
7952.63
diff:
-0.13
nom:
7953.00
rdg:
7942.00
diff:
-11.00

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found