Review measurement

2023-04-21 17:37

UP Meru S/M (2018)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

a9
nom:
6583
rdg:
7083
diff:
-20
a10
nom:
6480
rdg:
6986
diff:
-14
a11
nom:
6427
rdg:
6933
diff:
-14
a12
nom:
6443
rdg:
6949
diff:
-14
b9
nom:
6561
rdg:
7071
diff:
-10

Right riser

a9
nom:
6583
rdg:
7074
diff:
-29
a10
nom:
6480
rdg:
6978
diff:
-22
a11
nom:
6427
rdg:
6925
diff:
-22
a12
nom:
6443
rdg:
6944
diff:
-19
b9
nom:
6561
rdg:
7063
diff:
-18

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

Right riser

nom:
7018.80
rdg:
6996.80
diff:
-22.00
nom:
7009.00
rdg:
6998.00
diff:
-11.00

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (-9) of the deviations of all measurements from their nominal values.

No issues were found