Review measurement

2023-04-21 17:37

UP Meru S/M (2018)

In-group deviations

Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

a9
nom:
6583
rdg:
7083
diff:
-20
a10
nom:
6480
rdg:
6986
diff:
-14
a11
nom:
6427
rdg:
6933
diff:
-14
a12
nom:
6443
rdg:
6949
diff:
-14
b9
nom:
6561
rdg:
7071
diff:
-10

Right riser

a9
nom:
6583
rdg:
7074
diff:
-29
a10
nom:
6480
rdg:
6978
diff:
-22
a11
nom:
6427
rdg:
6925
diff:
-22
a12
nom:
6443
rdg:
6944
diff:
-19
b9
nom:
6561
rdg:
7063
diff:
-18

Trim

Groups arranged behind each other in flight direction having more than 10 mm deviation.

This should be corrected.

Left riser

Right riser

nom:
7018.80
rdg:
6996.80
diff:
-22.00
nom:
7009.00
rdg:
6998.00
diff:
-11.00

Group deviations

Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found