Review measurement

2026-03-24 20:27

Ozone Zeno 2 L (2022)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
7585
rdg:
7562
diff:
-23
A10
nom:
7451
rdg:
7428
diff:
-23
A11
nom:
7379
rdg:
7355
diff:
-24
A12
nom:
7335
rdg:
7299
diff:
-36
A13
nom:
7314
rdg:
7281
diff:
-33
A14
nom:
7357
rdg:
7320
diff:
-37
B12
nom:
7344
rdg:
7310
diff:
-34
B13
nom:
7352
rdg:
7321
diff:
-31
B14
nom:
7382
rdg:
7350
diff:
-32

Right riser

A9
nom:
7585
rdg:
7556
diff:
-29
A10
nom:
7451
rdg:
7426
diff:
-25
A11
nom:
7379
rdg:
7353
diff:
-26
A12
nom:
7335
rdg:
7280
diff:
-55
A13
nom:
7314
rdg:
7260
diff:
-54
A14
nom:
7357
rdg:
7296
diff:
-61
B12
nom:
7344
rdg:
7290
diff:
-54
B13
nom:
7352
rdg:
7299
diff:
-53
B14
nom:
7382
rdg:
7322
diff:
-60

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

This should be corrected.

Left riser

nom:
7471.67
rdg:
7448.33
diff:
1.67

Right riser

nom:
7471.67
rdg:
7445.00
diff: