Review measurement
2026-03-24 20:27
Ozone Zeno 2 L (2022)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
A9
nom:
7585
rdg:
7556
diff:
-29
A10
nom:
7451
rdg:
7426
diff:
-25
A11
nom:
7379
rdg:
7353
diff:
-26
A12
nom:
7335
rdg:
7280
diff:
-55
A13
nom:
7314
rdg:
7260
diff:
-54
A14
nom:
7357
rdg:
7296
diff:
-61
B12
nom:
7344
rdg:
7290
diff:
-54
B13
nom:
7352
rdg:
7299
diff:
-53
B14
nom:
7382
rdg:
7322
diff:
-60
Trim
Groups arranged behind each other in flight direction having more than 10
No issues were found
Group deviations
Groups that are more than 20
The measurement baseline is the median of the deviations of all measurements from their nominal values.
This should be corrected.
Left riser
nom:
7471.67
rdg:
7448.33
diff:
1.67
Right riser
nom:
7471.67
rdg:
7445.00
diff:
-1.67