Review measurement

2026-05-31 18:46

Ozone Photon MS (2023)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A1a
nom:
7258
rdg:
7387
diff:
+129
A2a
nom:
7157
rdg:
7280
diff:
+123
A3a
nom:
7121
rdg:
7240
diff:
+119
A4a
nom:
7153
rdg:
7273
diff:
+120
A1b
nom:
7243
rdg:
7363
diff:
+120
A2b
nom:
7141
rdg:
7263
diff:
+122
A3b
nom:
7107
rdg:
7228
diff:
+121
A4b
nom:
7140
rdg:
7256
diff:
+116

Right riser

A1a
nom:
7258
rdg:
7376
diff:
+118
A2a
nom:
7157
rdg:
7273
diff:
+116
A3a
nom:
7121
rdg:
7235
diff:
+114
A4a
nom:
7153
rdg:
7268
diff:
+115
A1b
nom:
7243
rdg:
7360
diff:
+117
A2b
nom:
7141
rdg:
7259
diff:
+118
A3b
nom:
7107
rdg:
7222
diff:
+115
A4b
nom:
7140
rdg:
7256
diff:
+116

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found