Review measurement

2025-11-28 12:53

Ozone Photon S (2023)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A1a
nom:
6979
rdg:
6985
diff:
 +6
A2a
nom:
6882
rdg:
6880
diff:
 -2
A3a
nom:
6847
rdg:
6844
diff:
 -3
A4a
nom:
6878
rdg:
6877
diff:
 -1
A1b
nom:
6965
rdg:
6969
diff:
 +4
A2b
nom:
6867
rdg:
6866
diff:
 -1
A3b
nom:
6833
rdg:
6832
diff:
 -1
A4b
nom:
6865
rdg:
6867
diff:
 +2

Right riser

A1a
nom:
6979
rdg:
6981
diff:
 +2
A2a
nom:
6882
rdg:
6881
diff:
 -1
A3a
nom:
6847
rdg:
6846
diff:
 -1
A4a
nom:
6878
rdg:
6878
diff:
 +0
A1b
nom:
6965
rdg:
6970
diff:
 +5
A2b
nom:
6867
rdg:
6861
diff:
 -6
A3b
nom:
6833
rdg:
6831
diff:
 -2
A4b
nom:
6865
rdg:
6865
diff:
 +0

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

Right riser

nom:
6676.50
rdg:
6666.38
diff:
-10.13
nom:
6670.88
rdg:
6675.25
diff:
4.38
nom:
6345.67
rdg:
6340.00
diff:
-5.67
nom:
6349.00
rdg:
6357.33
diff:
8.33

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found