Review measurement

2024-04-15 20:15

Niviuk Artik R 21 (2023)

In-group deviations

Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

a15
nom:
6428
rdg:
6440
diff:
+12
a16
nom:
6381
rdg:
6385
diff:
+4
c15
nom:
6425
rdg:
6440
diff:
+15
c16
nom:
6405
rdg:
6410
diff:
+5
c5
nom:
7022
rdg:
7045
diff:
+23
c6
nom:
6980
rdg:
7008
diff:
+28
c7
nom:
6920
rdg:
6942
diff:
+22
c8
nom:
6922
rdg:
6942
diff:
+20
d5
nom:
7135
rdg:
7152
diff:
+17
d6
nom:
7096
rdg:
7115
diff:
+19
d7
nom:
7025
rdg:
7042
diff:
+17
d8
nom:
7015
rdg:
7035
diff:
+20
c9
nom:
6793
rdg:
6813
diff:
+20
c10
nom:
6741
rdg:
6760
diff:
+19
c11
nom:
6634
rdg:
6655
diff:
+21
c12
nom:
6611
rdg:
6632
diff:
+21
c13
nom:
6604
rdg:
6620
diff:
+16
c14
nom:
6626
rdg:
6638
diff:
+12
d9
nom:
6923
rdg:
6940
diff:
+17
d10
nom:
6871
rdg:
6888
diff:
+17
d11
nom:
6730
rdg:
6750
diff:
+20
d12
nom:
6701
rdg:
6728
diff:
+27
d13
nom:
6674
rdg:
6688
diff:
+14
d14
nom:
6684
rdg:
6695
diff:
+11

Right riser

a15
nom:
6428
rdg:
6440
diff:
+12
a16
nom:
6381
rdg:
6390
diff:
+9
c15
nom:
6425
rdg:
6440
diff:
+15
c16
nom:
6405
rdg:
6415
diff:
+10
c5
nom:
7022
rdg:
7043
diff:
+21
c6
nom:
6980
rdg:
7005
diff:
+25
c7
nom:
6920
rdg:
6940
diff:
+20
c8
nom:
6922
rdg:
6942
diff:
+20
d5
nom:
7135
rdg:
7155
diff:
+20
d6
nom:
7096
rdg:
7115
diff:
+19
d7
nom:
7025
rdg:
7042
diff:
+17
d8
nom:
7015
rdg:
7035
diff:
+20
c9
nom:
6793
rdg:
6815
diff:
+22
c10
nom:
6741
rdg:
6764
diff:
+23
c11
nom:
6634
rdg:
6650
diff:
+16
c12
nom:
6611
rdg:
6630
diff:
+19
c13
nom:
6604
rdg:
6625
diff:
+21
c14
nom:
6626
rdg:
6645
diff:
+19
d9
nom:
6923
rdg:
6940
diff:
+17
d10
nom:
6871
rdg:
6890
diff:
+19
d11
nom:
6730
rdg:
6750
diff:
+20
d12
nom:
6701
rdg:
6725
diff:
+24
d13
nom:
6674
rdg:
6690
diff:
+16
d14
nom:
6684
rdg:
6695
diff:
+11

Trim

Groups arranged behind each other in flight direction having more than 10 mm deviation.

No issues were found

Group deviations

Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found

Buy us a