Review measurement
2026-04-14 20:09
Ozone Alpina 4 ML (2020)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
A9
nom:
7024
rdg:
6951
diff:
-73
A10
nom:
6985
rdg:
6911
diff:
-74
A11
nom:
6900
rdg:
6827
diff:
-73
A12
nom:
6885
rdg:
6808
diff:
-77
A13
nom:
6797
rdg:
6729
diff:
-68
A14
nom:
6800
rdg:
6731
diff:
-69
Trim
Groups arranged behind each other in flight direction having more than 10
This should be corrected.
Left riser
nom:
7417.50
rdg:
7379.25
diff:
-38.25
nom:
7349.25
rdg:
7298.50
diff:
-50.75
nom:
7517.20
rdg:
7464.90
diff:
-52.30
nom:
6898.50
rdg:
6837.33
diff:
-61.17
nom:
6960.54
rdg:
6914.69
diff:
-45.85
Right riser
nom:
7222.25
rdg:
7173.00
diff:
-49.25
nom:
7170.00
rdg:
7110.00
diff:
-60.00
nom:
7323.60
rdg:
7270.10
diff:
-53.50
nom:
6898.50
rdg:
6826.17
diff:
-72.33
nom:
6960.54
rdg:
6906.23
diff:
-54.31
Group deviations
Groups that are more than 20
The measurement baseline is the median of the deviations of all measurements from their nominal values.
This should be corrected.
Left riser
nom:
6898.50
rdg:
6837.33
diff:
-9.17
Right riser
nom:
6898.50
rdg:
6826.17
diff:
-20.33