Review measurement

2025-02-04 00:17

Ozone Enzo 3 M (2017)

In-group deviations

Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

B17
nom:
7703
rdg:
7709
diff:
+6
B18
nom:
7639
rdg:
7644
diff:
+5
B19
nom:
7621
rdg:
7627
diff:
+6
B20
nom:
7546
rdg:
7554
diff:
+8
B21
nom:
7550
rdg:
7555
diff:
+5
B22
nom:
7504
rdg:
7509
diff:
+5
B23
nom:
7512
rdg:
7512
diff:
+0

Right riser

B17
nom:
7703
rdg:
7707
diff:
+4
B18
nom:
7639
rdg:
7644
diff:
+5
B19
nom:
7621
rdg:
7628
diff:
+7
B20
nom:
7546
rdg:
7552
diff:
+6
B21
nom:
7550
rdg:
7556
diff:
+6
B22
nom:
7504
rdg:
7509
diff:
+5
B23
nom:
7512
rdg:
7508
diff:
-4

Trim

Groups arranged behind each other in flight direction having more than 10 mm deviation.

This should be corrected.

Left riser

nom:
7952.75
rdg:
7947.38
diff:
-5.38
nom:
7953.00
rdg:
7961.75
diff:
+8.75

Right riser

nom:
7952.75
rdg:
7948.50
diff:
-4.25
nom:
7953.00
rdg:
7961.88
diff:
+8.88

Group deviations

Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found