Review measurement
2026-06-28 14:01
Ozone Zeno 2 MS (2022)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
A9
nom:
6992
rdg:
6959
diff:
-33
A10
nom:
6871
rdg:
6841
diff:
-30
A11
nom:
6806
rdg:
6773
diff:
-33
A12
nom:
6761
rdg:
6719
diff:
-42
A13
nom:
6742
rdg:
6700
diff:
-42
A14
nom:
6782
rdg:
6736
diff:
-46
B12
nom:
6769
rdg:
6728
diff:
-41
B13
nom:
6778
rdg:
6735
diff:
-43
B14
nom:
6805
rdg:
6761
diff:
-44
Trim
Groups arranged behind each other in flight direction having more than 10
No issues were found
Group deviations
Groups that are more than 20
The measurement baseline is the median (-24) of the deviations of all measurements from their nominal values.