Review measurement

2025-07-20 19:17

Ozone Alpina 3 ML (2017)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
6549
rdg:
7049
diff:
 +0
A10
nom:
6515
rdg:
7010
diff:
 -5
A11
nom:
6433
rdg:
6929
diff:
 -4
A12
nom:
6415
rdg:
6907
diff:
 -8
A13
nom:
6326
rdg:
6819
diff:
 -7
A14
nom:
6320
rdg:
6810
diff:
-10

Right riser

A9
nom:
6549
rdg:
7048
diff:
 -1
A10
nom:
6515
rdg:
7016
diff:
 +1
A11
nom:
6433
rdg:
6931
diff:
 -2
A12
nom:
6415
rdg:
6912
diff:
 -3
A13
nom:
6326
rdg:
6819
diff:
 -7
A14
nom:
6320
rdg:
6809
diff:
-11

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

Right riser

nom:
7215.50
rdg:
7215.75
diff:
0.25
nom:
7142.75
rdg:
7131.00
diff:
-11.75
nom:
7297.40
rdg:
7290.30
diff:
-7.10

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (-4) of the deviations of all measurements from their nominal values.

No issues were found