Review measurement

2025-07-20 19:17

Ozone Alpina 3 ML (2017)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
6549
rdg:
7049
diff:
 +0
A10
nom:
6515
rdg:
7010
diff:
 -5
A11
nom:
6433
rdg:
6929
diff:
 -4
A12
nom:
6415
rdg:
6907
diff:
 -8
A13
nom:
6326
rdg:
6819
diff:
 -7
A14
nom:
6320
rdg:
6810
diff:
-10

Right riser

A9
nom:
6549
rdg:
7048
diff:
 -1
A10
nom:
6515
rdg:
7016
diff:
 +1
A11
nom:
6433
rdg:
6931
diff:
 -2
A12
nom:
6415
rdg:
6912
diff:
 -3
A13
nom:
6326
rdg:
6819
diff:
 -7
A14
nom:
6320
rdg:
6809
diff:
-11

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

Right riser

nom:
7215.50
rdg:
7215.75
diff:
0.25
nom:
7142.75
rdg:
7131.00
diff:
-11.75
nom:
7297.40
rdg:
7290.30
diff:
-7.10

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found