Review measurement
2025-07-20 19:17
Ozone Alpina 3 ML (2017)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
A9
nom:
7049
rdg:
7048
diff:
-1
A10
nom:
7015
rdg:
7016
diff:
+1
A11
nom:
6933
rdg:
6931
diff:
-2
A12
nom:
6915
rdg:
6912
diff:
-3
A13
nom:
6826
rdg:
6819
diff:
-7
A14
nom:
6820
rdg:
6809
diff:
-11
Trim
Groups arranged behind each other in flight direction having more than 10
This should be corrected.
Left riser
Right riser
nom:
7215.50
rdg:
7215.75
diff:
0.25
nom:
7142.75
rdg:
7131.00
diff:
-11.75
nom:
7297.40
rdg:
7290.30
diff:
-7.10
Group deviations
Groups that are more than 20
The measurement baseline is the median (-4) of the deviations of all measurements from their nominal values.
No issues were found