Review measurement
2024-03-24 10:51
Ozone Photon S (2023)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
A9
nom:
6444
rdg:
6475
diff:
+31
A10
nom:
6327
rdg:
6361
diff:
+34
A11
nom:
6266
rdg:
6298
diff:
+32
A12
nom:
6189
rdg:
6228
diff:
+39
A13
nom:
6183
rdg:
6222
diff:
+39
B12
nom:
6208
rdg:
6246
diff:
+38
B13
nom:
6209
rdg:
6248
diff:
+39
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
No issues were found
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found