Review measurement

2024-03-29 09:13

Ozone Zeno 2 ML (2022)

In-group deviations

Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
7238
rdg:
7220
diff:
-18
A10
nom:
7112
rdg:
7100
diff:
-12
A11
nom:
7043
rdg:
7037
diff:
-6
A12
nom:
6996
rdg:
6989
diff:
-7
A13
nom:
6976
rdg:
6964
diff:
-12
A14
nom:
7018
rdg:
7009
diff:
-9
B12
nom:
7005
rdg:
6992
diff:
-13
B13
nom:
7013
rdg:
7003
diff:
-10
B14
nom:
7041
rdg:
7032
diff:
-9

Right riser

A9
nom:
7238
rdg:
7217
diff:
-21
A10
nom:
7112
rdg:
7098
diff:
-14
A11
nom:
7043
rdg:
7030
diff:
-13
A12
nom:
6996
rdg:
6987
diff:
-9
A13
nom:
6976
rdg:
6970
diff:
-6
A14
nom:
7018
rdg:
7006
diff:
-12
B12
nom:
7005
rdg:
6990
diff:
-15
B13
nom:
7013
rdg:
6998
diff:
-15
B14
nom:
7041
rdg:
7035
diff:
-6

Trim

Groups arranged behind each other in flight direction having more than 10 mm deviation.

No issues were found

Group deviations

Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found