Review measurement

2024-02-17 12:21

Ozone Zeno 2 MS (2022)

In-group deviations

Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A5a
nom:
7435
rdg:
7442
diff:
+7
A6a
nom:
7281
rdg:
7283
diff:
+2
A7a
nom:
7206
rdg:
7207
diff:
+1
A8a
nom:
7233
rdg:
7238
diff:
+5
A5b
nom:
7425
rdg:
7430
diff:
+5
A6b
nom:
7273
rdg:
7273
diff:
+0
A7b
nom:
7201
rdg:
7202
diff:
+1
A8b
nom:
7230
rdg:
7229
diff:
-1
A9
nom:
6992
rdg:
6996
diff:
+4
A10
nom:
6871
rdg:
6874
diff:
+3
A11
nom:
6806
rdg:
6809
diff:
+3
A12
nom:
6761
rdg:
6755
diff:
-6
A13
nom:
6742
rdg:
6738
diff:
-4
A14
nom:
6782
rdg:
6777
diff:
-5
B12
nom:
6769
rdg:
6767
diff:
-2
B13
nom:
6778
rdg:
6772
diff:
-6
B14
nom:
6805
rdg:
6801
diff:
-4
B5
nom:
7399
rdg:
7400
diff:
+1
B6
nom:
7262
rdg:
7267
diff:
+5
B7
nom:
7186
rdg:
7188
diff:
+2
B8
nom:
7197
rdg:
7198
diff:
+1
C5
nom:
7475
rdg:
7484
diff:
+9
C6
nom:
7336
rdg:
7346
diff:
+10
C7
nom:
7255
rdg:
7257
diff:
+2
C8
nom:
7257
rdg:
7261
diff:
+4

Right riser

A5a
nom:
7435
rdg:
7446
diff:
+11
A6a
nom:
7281
rdg:
7287
diff:
+6
A7a
nom:
7206
rdg:
7209
diff:
+3
A8a
nom:
7233
rdg:
7235
diff:
+2
A5b
nom:
7425
rdg:
7426
diff:
+1
A6b
nom:
7273
rdg:
7280
diff:
+7
A7b
nom:
7201
rdg:
7203
diff:
+2
A8b
nom:
7230
rdg:
7227
diff:
-3
A9
nom:
6992
rdg:
6992
diff:
+0
A10
nom:
6871
rdg:
6872
diff:
+1
A11
nom:
6806
rdg:
6807
diff:
+1
A12
nom:
6761
rdg:
6754
diff:
-7
A13
nom:
6742
rdg:
6741
diff:
-1
A14
nom:
6782
rdg:
6769
diff:
-13
B12
nom:
6769
rdg:
6763
diff:
-6
B13
nom:
6778
rdg:
6778
diff:
+0
B14
nom:
6805
rdg:
6799
diff:
-6
B5
nom:
7399
rdg:
7408
diff:
+9
B6
nom:
7262
rdg:
7271
diff:
+9
B7
nom:
7186
rdg:
7194
diff:
+8
B8
nom:
7197
rdg:
7199
diff:
+2
C5
nom:
7475
rdg:
7484
diff:
+9
C6
nom:
7336
rdg:
7349
diff:
+13
C7
nom:
7255
rdg:
7263
diff:
+8
C8
nom:
7257
rdg:
7255
diff:
-2

Trim

Groups arranged behind each other in flight direction having more than 10 mm deviation.

No issues were found

Group deviations

Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found