Review measurement
2025-02-16 17:58
Ozone Zeolite 2 GT S (2023)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
A9
nom:
6585
rdg:
6557
diff:
-28
A10
nom:
6463
rdg:
6437
diff:
-26
A11
nom:
6397
rdg:
6371
diff:
-26
A12
nom:
6307
rdg:
6286
diff:
-21
A13
nom:
6288
rdg:
6264
diff:
-24
B12
nom:
6327
rdg:
6306
diff:
-21
B13
nom:
6310
rdg:
6285
diff:
-25
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
No issues were found
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found