Review measurement

2025-03-08 13:41

PHI Maestro Light 18 (2020)

Accuracy

Is calculated by comparing each suspension point's length change to the main line's overall change after re-measurement. Deviations over 3.0mm from the average are considered noticeable and may distort the trim result.

Left riser

avg change:
6.50
std dev:
1.38
1A1
dev:
-1.5
1A2
dev:
-0.5
1A3
dev:
-0.5
1A4
dev:
+2.5
1A5
dev:
-0.5
1A6
dev:
+0.5
avg change:
15.17
std dev:
2.32
1A7
dev:
+3.2
1A8
dev:
-0.8
1A9
dev:
-3.8
1A10
dev:
+1.2
1A11
dev:
+0.2
1A12
dev:
+0.2
avg change:
9.60
std dev:
1.67
1A13
dev:
-0.4
1StA
dev:
+2.6
1B13
dev:
-1.4
1StB
dev:
+0.6
1StC
dev:
-1.4
avg change:
0.50
std dev:
1.22
1B1
dev:
+0.5
1B2
dev:
+0.5
1B3
dev:
+0.5
1B4
dev:
+0.5
1B5
dev:
-2.5
1B6
dev:
+0.5
avg change:
10.17
std dev:
0.75
1B7
dev:
+1.2
1B8
dev:
+0.2
1B9
dev:
+0.2
1B10
dev:
-0.8
1B11
dev:
+0.2
1B12
dev:
-0.8
avg change:
0.33
std dev:
0.82
1C1
dev:
-0.3
1C2
dev:
-0.3
1C3
dev:
-0.3
1C4
dev:
+1.7
1C5
dev:
-0.3
1C6
dev:
-0.3
avg change:
12.67
std dev:
1.75
1C7
dev:
+1.7
1C8
dev:
+0.7
1C9
dev:
+0.7
1C10
dev:
-3.3
1C11
dev:
-0.3
1C12
dev:
+0.7

Right riser

avg change:
10.67
std dev:
1.03
1A1
dev:
+1.7
1A2
dev:
-0.3
1A3
dev:
-0.3
1A4
dev:
-1.3
1A5
dev:
-0.3
1A6
dev:
+0.7
avg change:
12.33
std dev:
1.37
1A7
dev:
+1.3
1A8
dev:
+1.3
1A9
dev:
+0.3
1A10
dev:
-1.7
1A11
dev:
-1.7
1A12
dev:
+0.3
avg change:
9.00
std dev:
0.71
1A13
dev:
0.0
1StA
dev:
0.0
1B13
dev:
-1.0
1StB
dev:
0.0
1StC
dev:
+1.0
avg change:
7.17
std dev:
1.47
1B1
dev:
+2.2
1B2
dev:
+1.2
1B3
dev:
-0.8
1B4
dev:
-1.8
1B5
dev:
-0.8
1B6
dev:
+0.2
avg change:
11.17
std dev:
0.75
1B7
dev:
-0.8
1B8
dev:
-0.8
1B9
dev:
+0.2
1B10
dev:
+0.2
1B11
dev:
+1.2
1B12
dev:
+0.2
avg change:
5.33
std dev:
2.07
1C1
dev:
+0.3
1C2
dev:
+3.3
1C3
dev:
+0.3
1C4
dev:
+0.3
1C5
dev:
-2.7
1C6
dev:
-1.7
avg change:
15.33
std dev:
1.21
1C7
dev:
+2.3
1C8
dev:
-0.7
1C9
dev:
+0.3
1C10
dev:
-0.7
1C11
dev:
-0.7
1C12
dev:
-0.7

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

1A13
nom:
5920
rdg:
6460
diff:
 +0
1StA
nom:
5800
rdg:
6331
diff:
 -9
1B13
nom:
5937
rdg:
6477
diff:
 +0
1StB
nom:
5882
rdg:
6411
diff:
-11
1StC
nom:
5986
rdg:
6504
diff:
-22
1C1
nom:
6761
rdg:
7285
diff:
-16
1C2
nom:
6732
rdg:
7258
diff:
-14
1C3
nom:
6620
rdg:
7153
diff:
 -7
1C4
nom:
6625
rdg:
7163
diff:
 -2
1C5
nom:
6657
rdg:
7191
diff:
 -6
1C6
nom:
6687
rdg:
7222
diff:
 -5

Right riser

1A13
nom:
5920
rdg:
6466
diff:
 +6
1StA
nom:
5800
rdg:
6335
diff:
 -5
1B13
nom:
5937
rdg:
6481
diff:
 +4
1StB
nom:
5882
rdg:
6413
diff:
 -9
1StC
nom:
5986
rdg:
6513
diff:
-13
1C1
nom:
6761
rdg:
7282
diff:
-19
1C2
nom:
6732
rdg:
7255
diff:
-17
1C3
nom:
6620
rdg:
7149
diff:
-11
1C4
nom:
6625
rdg:
7160
diff:
 -5
1C5
nom:
6657
rdg:
7192
diff:
 -5
1C6
nom:
6687
rdg:
7218
diff:
 -9

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found