Review measurement

2025-06-21 13:23

PHI Maestro 2 21 (2022)

Accuracy

Is calculated by comparing each suspension point's length change to the main line's overall change after re-measurement. Deviations over 3.0mm from the average are considered noticeable and may distort the trim result.

Left riser

avg change:
115.50
std dev:
164.86
1C9
dev:
-150.5
1C10
dev:
-88.5
1C11
dev:
-81.5
1C12
dev:
-95.5
1C13
dev:
+168.5
1C14
dev:
+247.5

Right riser

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

1A15
nom:
6155
rdg:
6724
diff:
-31
1A16
nom:
6051
rdg:
6626
diff:
-25
1B15
nom:
6207
rdg:
6766
diff:
-41
1B16
nom:
6095
rdg:
6668
diff:
-27
1C15
nom:
6236
rdg:
6799
diff:
-37
1B9
nom:
6664
rdg:
7232
diff:
-32
1B10
nom:
6576
rdg:
7149
diff:
-27
1B11
nom:
6572
rdg:
7147
diff:
-25
1B12
nom:
6505
rdg:
7080
diff:
-25
1B13
nom:
6448
rdg:
7020
diff:
-28
1B14
nom:
6461
rdg:
7021
diff:
-40
1C1
nom:
6976
rdg:
7530
diff:
-46
1C2
nom:
6894
rdg:
7449
diff:
-45
1C3
nom:
6845
rdg:
7411
diff:
-34
1C4
nom:
6843
rdg:
7409
diff:
-34
1D1
nom:
7083
rdg:
7632
diff:
-51
1D2
nom:
7006
rdg:
7556
diff:
-50
1D3
nom:
6980
rdg:
7540
diff:
-40
1D4
nom:
6972
rdg:
7532
diff:
-40

Right riser

1A15
nom:
6155
rdg:
6725
diff:
-30
1A16
nom:
6051
rdg:
6626
diff:
-25
1B15
nom:
6207
rdg:
6772
diff:
-35
1B16
nom:
6095
rdg:
6662
diff:
-33
1C15
nom:
6236
rdg:
6799
diff:
-37
1B9
nom:
6664
rdg:
7235
diff:
-29
1B10
nom:
6576
rdg:
7150
diff:
-26
1B11
nom:
6572
rdg:
7145
diff:
-27
1B12
nom:
6505
rdg:
7078
diff:
-27
1B13
nom:
6448
rdg:
7019
diff:
-29
1B14
nom:
6461
rdg:
7027
diff:
-34
1C1
nom:
6976
rdg:
7533
diff:
-43
1C2
nom:
6894
rdg:
7456
diff:
-38
1C3
nom:
6845
rdg:
7414
diff:
-31
1C4
nom:
6843
rdg:
7412
diff:
-31
1D1
nom:
7083
rdg:
7633
diff:
-50
1D2
nom:
7006
rdg:
7562
diff:
-44
1D3
nom:
6980
rdg:
7546
diff:
-34
1D4
nom:
6972
rdg:
7535
diff:
-37

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
7482.50
rdg:
7454.50
diff:
-28.00
nom:
7432.50
rdg:
7403.25
diff:
-29.25
nom:
7549.88
rdg:
7507.38
diff:
-42.50
nom:
7395.50
rdg:
7363.00
diff:
-32.50
nom:
7354.75
rdg:
7403.25
diff:
-29.25
nom:
7482.88
rdg:
7507.38
diff:
-42.50
nom:
7192.83
rdg:
7164.17
diff:
-28.67
nom:
7137.67
rdg:
7108.17
diff:
-29.50
nom:
7185.00
rdg:
7128.50
diff:
-56.50

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (-31) of the deviations of all measurements from their nominal values.

This should be corrected.

Left riser

nom:
7185.00
rdg:
7128.50
diff:
-56.50

Right riser

nom:
7185.00
rdg:
7159.17
diff:
-25.83