Review measurement

2025-07-26 12:48

Advance Epsilon 9 28 (2018)

Accuracy

Is calculated by comparing each suspension point's length change to the main line's overall change after re-measurement. Deviations over 3.0mm from the average are considered noticeable and may distort the trim result.

Left riser

Right riser

avg change:
4.50
std dev:
0.71
1B1
dev:
+0.5
1B2
dev:
-0.5

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

1C1
nom:
7377
rdg:
7365
diff:
-12
1C2
nom:
7320
rdg:
7296
diff:
-24
1D1
nom:
7515
rdg:
7505
diff:
-10
1D2
nom:
7457
rdg:
7427
diff:
-30

Right riser

1C1
nom:
7377
rdg:
7364
diff:
-13
1C2
nom:
7320
rdg:
7306
diff:
-14
1D1
nom:
7515
rdg:
7504
diff:
-11
1D2
nom:
7457
rdg:
7441
diff:
-16

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
6949.75
rdg:
6929.00
diff:
-20.75
nom:
6877.25
rdg:
6862.25
diff:
-15.00
nom:
6933.50
rdg:
6923.50
diff:
-10.00

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found