Review measurement
2024-06-20 18:04
Advance Omega Xalps 3 23 (2019)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
1C9
nom:
7243
rdg:
7285
diff:
+42
1C10
nom:
7179
rdg:
7220
diff:
+41
1C11
nom:
7046
rdg:
7093
diff:
+47
1C12
nom:
7020
rdg:
7070
diff:
+50
1C13
nom:
6927
rdg:
6973
diff:
+46
1C14
nom:
6911
rdg:
6955
diff:
+44
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
This should be corrected.
Left riser
nom:
7389.38
rdg:
7443.38
diff:
+54.00
nom:
7405.88
rdg:
7441.13
diff:
+35.25
Right riser
nom:
7389.38
rdg:
7437.50
diff:
+48.13
nom:
7405.88
rdg:
7441.38
diff:
+35.50
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found