Review measurement

2025-06-09 19:35

Ozone Delta 4 ML (2020)

Accuracy

Is calculated by comparing each suspension point's length change to the main line's overall change after re-measurement. Deviations over 3.0mm from the average are considered noticeable and may distort the trim result.

Left riser

avg change:
6.25
std dev:
1.26
A1
dev:
-1.8
A2
dev:
+0.3
A3
dev:
+0.3
A4
dev:
+1.3

Right riser

avg change:
7.75
std dev:
0.50
A1
dev:
+0.8
A2
dev:
-0.3
A3
dev:
-0.3
A4
dev:
-0.3

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

C7
nom:
7378
rdg:
7353
diff:
-25
C8
nom:
7303
rdg:
7277
diff:
-26
C9
nom:
7320
rdg:
7296
diff:
-24
C10
nom:
7270
rdg:
7256
diff:
-14
C11
nom:
7213
rdg:
7201
diff:
-12
C12
nom:
7256
rdg:
7244
diff:
-12
D5
nom:
7459
rdg:
7436
diff:
-23
D6
nom:
7390
rdg:
7370
diff:
-20
D7
nom:
7342
rdg:
7329
diff:
-13
D8
nom:
7305
rdg:
7293
diff:
-12

Right riser

C7
nom:
7378
rdg:
7351
diff:
-27
C8
nom:
7303
rdg:
7273
diff:
-30
C9
nom:
7320
rdg:
7293
diff:
-27
C10
nom:
7270
rdg:
7242
diff:
-28
C11
nom:
7213
rdg:
7185
diff:
-28
C12
nom:
7256
rdg:
7227
diff:
-29
D5
nom:
7459
rdg:
7431
diff:
-28
D6
nom:
7390
rdg:
7364
diff:
-26
D7
nom:
7342
rdg:
7319
diff:
-23
D8
nom:
7305
rdg:
7279
diff:
-26

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found

Buy us coffee