Review measurement
2024-12-04 11:28
AirDesign Volt 5 M (2024)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
A5a
nom:
7696
rdg:
7695
diff:
-1
A6a
nom:
7643
rdg:
7641
diff:
-2
A7a
nom:
7560
rdg:
7560
diff:
+0
A8a
nom:
7560
rdg:
7554
diff:
-6
A5b
nom:
7670
rdg:
7669
diff:
-1
A6b
nom:
7617
rdg:
7619
diff:
+2
A7b
nom:
7536
rdg:
7531
diff:
-5
A8b
nom:
7541
rdg:
7532
diff:
-9
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
No issues were found
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found