Review measurement
2024-05-06 08:41
AirDesign Volt 4 S (2022)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
B9
nom:
7183
rdg:
7159
diff:
-24
B10
nom:
7124
rdg:
7107
diff:
-17
B11
nom:
7023
rdg:
7008
diff:
-15
B12
nom:
7020
rdg:
7007
diff:
-13
C13
nom:
7241
rdg:
7223
diff:
-18
C14
nom:
7182
rdg:
7165
diff:
-17
Right riser
A13
nom:
6895
rdg:
6859
diff:
-36
A14
nom:
6787
rdg:
6767
diff:
-20
A15
nom:
6770
rdg:
6745
diff:
-25
B13
nom:
6860
rdg:
6834
diff:
-26
B14
nom:
6788
rdg:
6765
diff:
-23
B15
nom:
6781
rdg:
6761
diff:
-20
C15
nom:
6895
rdg:
6871
diff:
-24
C16
nom:
6819
rdg:
6796
diff:
-23
C17
nom:
6849
rdg:
6825
diff:
-24
B9
nom:
7183
rdg:
7166
diff:
-17
B10
nom:
7124
rdg:
7103
diff:
-21
B11
nom:
7023
rdg:
7010
diff:
-13
B12
nom:
7020
rdg:
7007
diff:
-13
C13
nom:
7241
rdg:
7222
diff:
-19
C14
nom:
7182
rdg:
7170
diff:
-12
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
No issues were found
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found