Review measurement

2025-06-27 14:57

Ozone Enzo 3 L (2017)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A5a
nom:
8402
rdg:
8413
diff:
+11
A6a
nom:
8249
rdg:
8254
diff:
 +5
A7a
nom:
8175
rdg:
8180
diff:
 +5
A8a
nom:
8204
rdg:
8204
diff:
 +0
A5b
nom:
8385
rdg:
8393
diff:
 +8
A6b
nom:
8232
rdg:
8241
diff:
 +9
A7b
nom:
8160
rdg:
8165
diff:
 +5
A8b
nom:
8192
rdg:
8194
diff:
 +2

Right riser

A5a
nom:
8402
rdg:
8401
diff:
 -1
A6a
nom:
8249
rdg:
8248
diff:
 -1
A7a
nom:
8175
rdg:
8173
diff:
 -2
A8a
nom:
8204
rdg:
8200
diff:
 -4
A5b
nom:
8385
rdg:
8388
diff:
 +3
A6b
nom:
8232
rdg:
8232
diff:
 +0
A7b
nom:
8160
rdg:
8156
diff:
 -4
A8b
nom:
8192
rdg:
8192
diff:
 +0

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

Right riser

nom:
8249.88
rdg:
8248.75
diff:
-1.13
nom:
8250.50
rdg:
8261.25
diff:
10.75

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found