Review measurement

2025-07-12 18:06

PHI Maestro Light 19 (2020)

Accuracy

Is calculated by comparing each suspension point's length change to the main line's overall change after re-measurement. Deviations over 3.0mm from the average are considered noticeable and may distort the trim result.

Left riser

avg change:
18.17
std dev:
1.83
1A1
dev:
+3.2
1A2
dev:
+1.2
1A3
dev:
-0.8
1A4
dev:
-1.8
1A5
dev:
-0.8
1A6
dev:
-0.8
avg change:
1.67
std dev:
1.75
1A7
dev:
-0.7
1A8
dev:
-1.7
1A9
dev:
-0.7
1A10
dev:
-0.7
1A11
dev:
+3.3
1A12
dev:
+0.3
avg change:
10.20
std dev:
2.17
1A13
dev:
-0.8
1StA
dev:
+2.2
1B13
dev:
-2.8
1StB
dev:
+2.2
1StC
dev:
-0.8
avg change:
10.50
std dev:
1.64
1B1
dev:
-1.5
1B2
dev:
+0.5
1B3
dev:
+0.5
1B4
dev:
+1.5
1B5
dev:
-2.5
1B6
dev:
+1.5
avg change:
6.17
std dev:
3.06
1B7
dev:
+2.2
1B8
dev:
+1.2
1B9
dev:
-0.8
1B10
dev:
+2.2
1B11
dev:
+1.2
1B12
dev:
-5.8
avg change:
9.83
std dev:
1.60
1C1
dev:
-0.2
1C2
dev:
-1.2
1C3
dev:
+0.8
1C4
dev:
+2.8
1C5
dev:
-1.2
1C6
dev:
-1.2
avg change:
5.17
std dev:
1.47
1C7
dev:
-0.8
1C8
dev:
+0.2
1C9
dev:
+2.2
1C10
dev:
+1.2
1C11
dev:
-0.8
1C12
dev:
-1.8

Right riser

avg change:
12.17
std dev:
1.60
1A1
dev:
+1.2
1A2
dev:
-0.8
1A3
dev:
+1.2
1A4
dev:
-2.8
1A5
dev:
+0.2
1A6
dev:
+1.2
avg change:
0.17
std dev:
3.60
1A7
dev:
+4.2
1A8
dev:
+2.2
1A9
dev:
-1.8
1A10
dev:
+2.2
1A11
dev:
-0.8
1A12
dev:
-5.8
avg change:
9.40
std dev:
2.07
1A13
dev:
+3.4
1StA
dev:
-1.6
1B13
dev:
-0.6
1StB
dev:
+0.4
1StC
dev:
-1.6
avg change:
16.17
std dev:
1.72
1B1
dev:
+0.2
1B2
dev:
-0.8
1B3
dev:
+3.2
1B4
dev:
-1.8
1B5
dev:
+0.2
1B6
dev:
-0.8
avg change:
5.50
std dev:
2.07
1B7
dev:
+2.5
1B8
dev:
+0.5
1B9
dev:
-0.5
1B10
dev:
+1.5
1B11
dev:
-3.5
1B12
dev:
-0.5
avg change:
10.50
std dev:
1.38
1C1
dev:
-2.5
1C2
dev:
+1.5
1C3
dev:
+0.5
1C4
dev:
+0.5
1C5
dev:
+0.5
1C6
dev:
-0.5
avg change:
6.17
std dev:
2.48
1C7
dev:
-0.8
1C8
dev:
+0.2
1C9
dev:
+2.2
1C10
dev:
+3.2
1C11
dev:
-0.8
1C12
dev:
-3.8

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

1B7
nom:
6386
rdg:
6893
diff:
-33
1B8
nom:
6281
rdg:
6791
diff:
-30
1B9
nom:
6295
rdg:
6802
diff:
-33
1B10
nom:
6166
rdg:
6671
diff:
-35
1B11
nom:
6096
rdg:
6601
diff:
-35
1B12
nom:
6097
rdg:
6592
diff:
-45
1A7
nom:
6447
rdg:
6954
diff:
-33
1A8
nom:
6336
rdg:
6845
diff:
-31
1A9
nom:
6348
rdg:
6859
diff:
-29
1A10
nom:
6213
rdg:
6721
diff:
-32
1A11
nom:
6133
rdg:
6642
diff:
-31
1A12
nom:
6138
rdg:
6642
diff:
-36

Right riser

1B7
nom:
6386
rdg:
6891
diff:
-35
1B8
nom:
6281
rdg:
6791
diff:
-30
1B9
nom:
6295
rdg:
6804
diff:
-31
1B10
nom:
6166
rdg:
6675
diff:
-31
1B11
nom:
6096
rdg:
6603
diff:
-33
1B12
nom:
6097
rdg:
6600
diff:
-37
1A7
nom:
6447
rdg:
6953
diff:
-34
1A8
nom:
6336
rdg:
6849
diff:
-27
1A9
nom:
6348
rdg:
6859
diff:
-29
1A10
nom:
6213
rdg:
6723
diff:
-30
1A11
nom:
6133
rdg:
6640
diff:
-33
1A12
nom:
6138
rdg:
6640
diff:
-38

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
7120.00
rdg:
7076.17
diff:
-43.83
nom:
7047.17
rdg:
7010.83
diff:
-36.33
nom:
7148.17
rdg:
7116.00
diff:
-32.17

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (-35) of the deviations of all measurements from their nominal values.

No issues were found