Review measurement
2026-05-06 20:07
Ozone Zeno 2 ML (2022)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
A9
nom:
7238
rdg:
7319
diff:
+81
A10
nom:
7112
rdg:
7197
diff:
+85
A11
nom:
7043
rdg:
7122
diff:
+79
A12
nom:
6996
rdg:
7069
diff:
+73
A13
nom:
6976
rdg:
7045
diff:
+69
A14
nom:
7018
rdg:
7083
diff:
+65
B12
nom:
7005
rdg:
7075
diff:
+70
B13
nom:
7013
rdg:
7084
diff:
+71
B14
nom:
7041
rdg:
7111
diff:
+70
Trim
Groups arranged behind each other in flight direction having more than 10
This should be corrected.
Left riser
Right riser
nom:
7131.00
rdg:
7212.67
diff:
81.67
nom:
7155.33
rdg:
7225.00
diff:
69.67
Group deviations
Groups that are more than 20
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found