Review measurement

2026-05-06 20:07

Ozone Zeno 2 ML (2022)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
7238
rdg:
7309
diff:
+71
A10
nom:
7112
rdg:
7190
diff:
+78
A11
nom:
7043
rdg:
7116
diff:
+73
A12
nom:
6996
rdg:
7058
diff:
+62
A13
nom:
6976
rdg:
7040
diff:
+64
A14
nom:
7018
rdg:
7074
diff:
+56
B12
nom:
7005
rdg:
7065
diff:
+60
B13
nom:
7013
rdg:
7074
diff:
+61
B14
nom:
7041
rdg:
7099
diff:
+58

Right riser

A9
nom:
7238
rdg:
7319
diff:
+81
A10
nom:
7112
rdg:
7197
diff:
+85
A11
nom:
7043
rdg:
7122
diff:
+79
A12
nom:
6996
rdg:
7069
diff:
+73
A13
nom:
6976
rdg:
7045
diff:
+69
A14
nom:
7018
rdg:
7083
diff:
+65
B12
nom:
7005
rdg:
7075
diff:
+70
B13
nom:
7013
rdg:
7084
diff:
+71
B14
nom:
7041
rdg:
7111
diff:
+70

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

Right riser

nom:
7131.00
rdg:
7212.67
diff:
81.67
nom:
7155.33
rdg:
7225.00
diff:
69.67

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found