Review measurement

2025-06-08 18:43

PHI Maestro Light 18 (2020)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

1A13
nom:
5920
rdg:
6462
diff:
 +2
1StA
nom:
5800
rdg:
6334
diff:
 -6
1B13
nom:
5937
rdg:
6478
diff:
 +1
1StB
nom:
5882
rdg:
6412
diff:
-10
1StC
nom:
5986
rdg:
6507
diff:
-19
1C1
nom:
6761
rdg:
7286
diff:
-15
1C2
nom:
6732
rdg:
7259
diff:
-13
1C3
nom:
6620
rdg:
7153
diff:
 -7
1C4
nom:
6625
rdg:
7162
diff:
 -3
1C5
nom:
6657
rdg:
7193
diff:
 -4
1C6
nom:
6687
rdg:
7222
diff:
 -5

Right riser

1A13
nom:
5920
rdg:
6466
diff:
 +6
1StA
nom:
5800
rdg:
6333
diff:
 -7
1B13
nom:
5937
rdg:
6479
diff:
 +2
1StB
nom:
5882
rdg:
6414
diff:
 -8
1StC
nom:
5986
rdg:
6510
diff:
-16
1C1
nom:
6761
rdg:
7280
diff:
-21
1C2
nom:
6732
rdg:
7252
diff:
-20
1C3
nom:
6620
rdg:
7146
diff:
-14
1C4
nom:
6625
rdg:
7159
diff:
 -6
1C5
nom:
6657
rdg:
7191
diff:
 -6
1C6
nom:
6687
rdg:
7216
diff:
-11

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found

Buy us coffee