Review measurement
2024-02-11 16:08
Ozone Photon S (2023)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
A1a
nom:
6979
rdg:
7004
diff:
+25
A2a
nom:
6882
rdg:
6905
diff:
+23
A3a
nom:
6847
rdg:
6865
diff:
+18
A4a
nom:
6878
rdg:
6900
diff:
+22
A1b
nom:
6965
rdg:
6988
diff:
+23
A2b
nom:
6867
rdg:
6891
diff:
+24
A3b
nom:
6833
rdg:
6853
diff:
+20
A4b
nom:
6865
rdg:
6885
diff:
+20
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
No issues were found
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found