Review measurement
2024-09-06 17:03
Ozone Zeno 2 MS (2022)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
A9
nom:
6992
rdg:
6985
diff:
-7
A10
nom:
6871
rdg:
6869
diff:
-2
A11
nom:
6806
rdg:
6803
diff:
-3
A12
nom:
6761
rdg:
6762
diff:
+1
A13
nom:
6742
rdg:
6744
diff:
+2
A14
nom:
6782
rdg:
6783
diff:
+1
B12
nom:
6769
rdg:
6772
diff:
+3
B13
nom:
6778
rdg:
6778
diff:
+0
B14
nom:
6805
rdg:
6808
diff:
+3
Right riser
A1a
nom:
7651
rdg:
7650
diff:
-1
A2a
nom:
7543
rdg:
7541
diff:
-2
A3a
nom:
7506
rdg:
7507
diff:
+1
A4a
nom:
7539
rdg:
7536
diff:
-3
A1b
nom:
7636
rdg:
7637
diff:
+1
A2b
nom:
7528
rdg:
7525
diff:
-3
A3b
nom:
7492
rdg:
7491
diff:
-1
A4b
nom:
7526
rdg:
7525
diff:
-1
A9
nom:
6992
rdg:
6987
diff:
-5
A10
nom:
6871
rdg:
6871
diff:
+0
A11
nom:
6806
rdg:
6803
diff:
-3
A12
nom:
6761
rdg:
6756
diff:
-5
A13
nom:
6742
rdg:
6737
diff:
-5
A14
nom:
6782
rdg:
6770
diff:
-12
B12
nom:
6769
rdg:
6767
diff:
-2
B13
nom:
6778
rdg:
6775
diff:
-3
B14
nom:
6805
rdg:
6795
diff:
-10
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
No issues were found
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found