Review measurement
2024-05-12 00:58
Ozone Zeno 2 L (2022)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
A1a
nom:
8295
rdg:
8280
diff:
-15
A2a
nom:
8181
rdg:
8166
diff:
-15
A3a
nom:
8140
rdg:
8126
diff:
-14
A4a
nom:
8176
rdg:
8162
diff:
-14
A1b
nom:
8281
rdg:
8267
diff:
-14
A2b
nom:
8166
rdg:
8150
diff:
-16
A3b
nom:
8126
rdg:
8108
diff:
-18
A4b
nom:
8164
rdg:
8147
diff:
-17
Right riser
A9
nom:
7585
rdg:
7563
diff:
-22
A10
nom:
7451
rdg:
7426
diff:
-25
A11
nom:
7379
rdg:
7355
diff:
-24
A12
nom:
7335
rdg:
7306
diff:
-29
A13
nom:
7314
rdg:
7270
diff:
-44
A14
nom:
7357
rdg:
7305
diff:
-52
B12
nom:
7344
rdg:
7303
diff:
-41
B13
nom:
7352
rdg:
7314
diff:
-38
B14
nom:
7382
rdg:
7338
diff:
-44
A1a
nom:
8295
rdg:
8278
diff:
-17
A2a
nom:
8181
rdg:
8171
diff:
-10
A3a
nom:
8140
rdg:
8125
diff:
-15
A4a
nom:
8176
rdg:
8160
diff:
-16
A1b
nom:
8281
rdg:
8267
diff:
-14
A2b
nom:
8166
rdg:
8150
diff:
-16
A3b
nom:
8126
rdg:
8109
diff:
-17
A4b
nom:
8164
rdg:
8140
diff:
-24
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
No issues were found
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found