Review measurement
2025-02-11 21:56
Ozone Enzo 3 S (2017)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
B1
nom:
8021
rdg:
8106
diff:
+85
B2
nom:
7972
rdg:
8059
diff:
+87
B3
nom:
7882
rdg:
7970
diff:
+88
B4
nom:
7878
rdg:
7966
diff:
+88
B5
nom:
7853
rdg:
7943
diff:
+90
B6
nom:
7844
rdg:
7939
diff:
+95
B7
nom:
7882
rdg:
7970
diff:
+88
B8
nom:
7909
rdg:
7998
diff:
+89
C1
nom:
8134
rdg:
8219
diff:
+85
C2
nom:
8088
rdg:
8173
diff:
+85
C3
nom:
7998
rdg:
8075
diff:
+77
C4
nom:
7993
rdg:
8073
diff:
+80
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
This should be corrected.
Left riser
nom:
7932.63
rdg:
8012.00
diff:
+79.38
nom:
7905.13
rdg:
7995.50
diff:
+90.38
nom:
7676.00
rdg:
7753.13
diff:
+77.13
nom:
7675.38
rdg:
7767.13
diff:
+91.75
Right riser
nom:
7676.00
rdg:
7754.88
diff:
+78.88
nom:
7675.38
rdg:
7768.75
diff:
+93.38
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found