Review measurement

2025-10-03 21:21

PHI Maestro Light 22 (2020)

Accuracy

Is calculated by comparing each suspension point's length change to the main line's overall change after re-measurement. Deviations over 3.0mm from the average are considered noticeable and may distort the trim result.

Left riser

avg change:
4.00
std dev:
6.96
1A7
dev:
+1.0
1A8
dev:
+4.0
1A9
dev:
+2.0
1A10
dev:
+4.0
1A11
dev:
+3.0
1A12
dev:
-14.0
avg change:
5.40
std dev:
2.07
1A13
dev:
+0.4
1StA
dev:
+1.4
1B13
dev:
+0.4
1StB
dev:
+1.4
1StC
dev:
-3.6

Right riser

avg change:
6.60
std dev:
1.14
1A13
dev:
-1.4
1StA
dev:
+1.6
1B13
dev:
-0.4
1StB
dev:
+0.6
1StC
dev:
-0.4

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

1A7
nom:
6936
rdg:
7444
diff:
-32
1A8
nom:
6815
rdg:
7327
diff:
-28
1A9
nom:
6829
rdg:
7340
diff:
-29
1A10
nom:
6682
rdg:
7184
diff:
-38
1A11
nom:
6596
rdg:
7098
diff:
-38
1A12
nom:
6601
rdg:
7121
diff:
-20

Right riser

1A7
nom:
6936
rdg:
7444
diff:
-32
1A8
nom:
6815
rdg:
7326
diff:
-29
1A9
nom:
6829
rdg:
7342
diff:
-27
1A10
nom:
6682
rdg:
7190
diff:
-32
1A11
nom:
6596
rdg:
7100
diff:
-36
1A12
nom:
6601
rdg:
7121
diff:
-20

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found

Buy us coffee