Review measurement

2025-07-02 18:52

Skywalk SAGE 105 (2024)

Accuracy

Is calculated by comparing each suspension point's length change to the main line's overall change after re-measurement. Deviations over 3.0mm from the average are considered noticeable and may distort the trim result.

Left riser

avg change:
7.25
std dev:
2.12
b5
dev:
+0.3
b6
dev:
-1.8
b7
dev:
+1.3
b8
dev:
+0.3
c5
dev:
-3.8
c6
dev:
-0.8
c7
dev:
+3.3
c8
dev:
+1.3
avg change:
9.00
std dev:
1.31
b9
dev:
+1.0
b10
dev:
+1.0
b11
dev:
+2.0
b12
dev:
0.0
b13
dev:
-1.0
b14
dev:
-1.0
b15
dev:
-2.0
b16
dev:
0.0

Right riser

avg change:
10.88
std dev:
0.99
b9
dev:
-1.1
b10
dev:
-0.1
b11
dev:
-0.1
b12
dev:
+1.9
b13
dev:
-1.1
b14
dev:
-0.1
b15
dev:
-0.1
b16
dev:
+0.9

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

b1
nom:
7627
rdg:
7650
diff:
+23
b2
nom:
7590
rdg:
7613
diff:
+23
b3
nom:
7536
rdg:
7559
diff:
+23
b4
nom:
7539
rdg:
7565
diff:
+26
c1
nom:
7697
rdg:
7711
diff:
+14
c2
nom:
7661
rdg:
7674
diff:
+13
c3
nom:
7606
rdg:
7623
diff:
+17
c4
nom:
7609
rdg:
7625
diff:
+16
b5
nom:
7444
rdg:
7463
diff:
+19
b6
nom:
7404
rdg:
7424
diff:
+20
b7
nom:
7335
rdg:
7355
diff:
+20
b8
nom:
7332
rdg:
7353
diff:
+21
c5
nom:
7497
rdg:
7504
diff:
 +7
c6
nom:
7456
rdg:
7465
diff:
 +9
c7
nom:
7386
rdg:
7396
diff:
+10
c8
nom:
7375
rdg:
7385
diff:
+10

Right riser

b1
nom:
7627
rdg:
7648
diff:
+21
b2
nom:
7590
rdg:
7610
diff:
+20
b3
nom:
7536
rdg:
7560
diff:
+24
b4
nom:
7539
rdg:
7565
diff:
+26
c1
nom:
7697
rdg:
7712
diff:
+15
c2
nom:
7661
rdg:
7678
diff:
+17
c3
nom:
7606
rdg:
7622
diff:
+16
c4
nom:
7609
rdg:
7626
diff:
+17
b5
nom:
7444
rdg:
7469
diff:
+25
b6
nom:
7404
rdg:
7431
diff:
+27
b7
nom:
7335
rdg:
7357
diff:
+22
b8
nom:
7332
rdg:
7357
diff:
+25
c5
nom:
7497
rdg:
7516
diff:
+19
c6
nom:
7456
rdg:
7473
diff:
+17
c7
nom:
7386
rdg:
7400
diff:
+14
c8
nom:
7375
rdg:
7390
diff:
+15

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found

Buy us coffee