Review measurement

2025-04-18 18:35

Ozone Photon ML (2023)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A5a
nom:
7324
rdg:
7316
diff:
 -8
A6a
nom:
7184
rdg:
7177
diff:
 -7
A7a
nom:
7112
rdg:
7114
diff:
 +2
A8a
nom:
7123
rdg:
7121
diff:
 -2
A5b
nom:
7313
rdg:
7310
diff:
 -3
A6b
nom:
7173
rdg:
7169
diff:
 -4
A7b
nom:
7104
rdg:
7109
diff:
 +5
A8b
nom:
7118
rdg:
7114
diff:
 -4

Right riser

A5a
nom:
7324
rdg:
7319
diff:
 -5
A6a
nom:
7184
rdg:
7183
diff:
 -1
A7a
nom:
7112
rdg:
7111
diff:
 -1
A8a
nom:
7123
rdg:
7117
diff:
 -6
A5b
nom:
7313
rdg:
7312
diff:
 -1
A6b
nom:
7173
rdg:
7171
diff:
 -2
A7b
nom:
7104
rdg:
7103
diff:
 -1
A8b
nom:
7118
rdg:
7112
diff:
 -6

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found