Review measurement
2025-11-19 13:20
Zoom X2C 95 (2024)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
a5a
nom:
6666
rdg:
7272
diff:
+66
a6a
nom:
6593
rdg:
7194
diff:
+61
a7a
nom:
6544
rdg:
7144
diff:
+60
a8a
nom:
6521
rdg:
7120
diff:
+59
a5b
nom:
6662
rdg:
7264
diff:
+62
a6b
nom:
6585
rdg:
7182
diff:
+57
a7b
nom:
6538
rdg:
7135
diff:
+57
a8b
nom:
6513
rdg:
7108
diff:
+55
Trim
Groups arranged behind each other in flight direction having more than 10
This should be corrected.
Left riser
nom:
6732.25
rdg:
6783.00
diff:
50.75
nom:
6713.75
rdg:
6781.75
diff:
68.00
Right riser
nom:
6732.25
rdg:
6781.50
diff:
49.25
nom:
6713.75
rdg:
6778.25
diff:
64.50
Group deviations
Groups that are more than 20
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found