Review measurement

2025-11-19 13:20

Zoom X2C 95 (2024)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

a5a
nom:
6666
rdg:
7272
diff:
+66
a6a
nom:
6593
rdg:
7194
diff:
+61
a7a
nom:
6544
rdg:
7147
diff:
+63
a8a
nom:
6521
rdg:
7119
diff:
+58
a5b
nom:
6662
rdg:
7264
diff:
+62
a6b
nom:
6585
rdg:
7185
diff:
+60
a7b
nom:
6538
rdg:
7138
diff:
+60
a8b
nom:
6513
rdg:
7113
diff:
+60

Right riser

a5a
nom:
6666
rdg:
7272
diff:
+66
a6a
nom:
6593
rdg:
7194
diff:
+61
a7a
nom:
6544
rdg:
7144
diff:
+60
a8a
nom:
6521
rdg:
7120
diff:
+59
a5b
nom:
6662
rdg:
7264
diff:
+62
a6b
nom:
6585
rdg:
7182
diff:
+57
a7b
nom:
6538
rdg:
7135
diff:
+57
a8b
nom:
6513
rdg:
7108
diff:
+55

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
6732.25
rdg:
6783.00
diff:
50.75
nom:
6713.75
rdg:
6781.75
diff:
68.00

Right riser

nom:
6732.25
rdg:
6781.50
diff:
49.25
nom:
6713.75
rdg:
6778.25
diff:
64.50

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found