Review measurement
2025-01-20 16:50
Ozone Zeno 2 MS (2022)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
A9
        nom:
6992
rdg:
7000
diff:
 +8
A10
        nom:
6871
rdg:
6882
diff:
+11
A11
        nom:
6806
rdg:
6814
diff:
 +8
A12
        nom:
6761
rdg:
6768
diff:
 +7
A13
        nom:
6742
rdg:
6754
diff:
+12
A14
        nom:
6782
rdg:
6785
diff:
 +3
B12
        nom:
6769
rdg:
6781
diff:
+12
B13
        nom:
6778
rdg:
6790
diff:
+12
B14
        nom:
6805
rdg:
6802
diff:
 -3
Trim
                            Groups arranged behind each other in flight direction having more than 10
This should be corrected.
Left riser
nom:
6889.67
            rdg:
6896.00
            diff:
6.33
            nom:
6913.33
            rdg:
6907.67
            diff:
-5.67
            Right riser
nom:
7285.50
            rdg:
7295.50
            diff:
10.00
            nom:
7295.88
            rdg:
7295.63
            diff:
-0.25
            nom:
6889.67
            rdg:
6898.67
            diff:
9.00
            nom:
6913.33
            rdg:
6906.33
            diff:
-7.00
            Group deviations
                                Groups that are more than 20
The measurement baseline is the median of the deviations of all measurements from their nominal values.
                            
No issues were found