Review measurement

2026-04-25 19:45

Ozone Swift 6 ML (2022)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
7001
rdg:
6946
diff:
-55
A10
nom:
6942
rdg:
6891
diff:
-51
A11
nom:
6851
rdg:
6801
diff:
-50
A12
nom:
6839
rdg:
6785
diff:
-54
A13
nom:
6738
rdg:
6692
diff:
-46
A14
nom:
6744
rdg:
6699
diff:
-45

Right riser

A9
nom:
7001
rdg:
6949
diff:
-52
A10
nom:
6942
rdg:
6895
diff:
-47
A11
nom:
6851
rdg:
6802
diff:
-49
A12
nom:
6839
rdg:
6790
diff:
-49
A13
nom:
6738
rdg:
6698
diff:
-40
A14
nom:
6744
rdg:
6696
diff:
-48

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
6852.50
rdg:
6802.33
diff:
-50.17
nom:
6845.17
rdg:
6807.17
diff:
-38.00

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found