Review measurement

2026-10-06 16:06

Niviuk Ikuma 3 P 24 (2023)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

c1
nom:
7191
rdg:
7181
diff:
-10
c2
nom:
7138
rdg:
7123
diff:
-15
c3
nom:
7099
rdg:
7085
diff:
-14
c4
nom:
7128
rdg:
7107
diff:
-21
d1
nom:
7269
rdg:
7258
diff:
-11
d2
nom:
7221
rdg:
7212
diff:
 -9
d3
nom:
7179
rdg:
7166
diff:
-13
d4
nom:
7201
rdg:
7186
diff:
-15

Right riser

c1
nom:
7191
rdg:
7181
diff:
-10
c2
nom:
7138
rdg:
7129
diff:
 -9
c3
nom:
7099
rdg:
7088
diff:
-11
c4
nom:
7128
rdg:
7114
diff:
-14
d1
nom:
7269
rdg:
7261
diff:
 -8
d2
nom:
7221
rdg:
7214
diff:
 -7
d3
nom:
7179
rdg:
7172
diff:
 -7
d4
nom:
7201
rdg:
7197
diff:
 -4

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (-12) of the deviations of all measurements from their nominal values.

No issues were found