Review measurement

2025-05-24 02:40

Ozone Photon L (2023)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
7150
rdg:
7361
diff:
+211
A10
nom:
7018
rdg:
7232
diff:
+214
A11
nom:
6946
rdg:
7162
diff:
+216
A12
nom:
6861
rdg:
7087
diff:
+226
A13
nom:
6853
rdg:
7076
diff:
+223
B12
nom:
6882
rdg:
7104
diff:
+222
B13
nom:
6881
rdg:
7104
diff:
+223

Right riser

A9
nom:
7150
rdg:
7363
diff:
+213
A10
nom:
7018
rdg:
7234
diff:
+216
A11
nom:
6946
rdg:
7160
diff:
+214
A12
nom:
6861
rdg:
7086
diff:
+225
A13
nom:
6853
rdg:
7077
diff:
+224
B12
nom:
6882
rdg:
7107
diff:
+225
B13
nom:
6881
rdg:
7104
diff:
+223

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
7404.00
rdg:
7615.63
diff:
211.63
nom:
7413.88
rdg:
7637.75
diff:
223.88

Right riser

nom:
7404.00
rdg:
7614.75
diff:
210.75
nom:
7413.88
rdg:
7637.63
diff:
223.75

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found

Buy us coffee