Review measurement
2025-07-06 12:54
Ozone Enzo 3 S (2017)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
B1
nom:
8021
rdg:
8018
diff:
-3
B2
nom:
7972
rdg:
7975
diff:
+3
B3
nom:
7882
rdg:
7884
diff:
+2
B4
nom:
7878
rdg:
7882
diff:
+4
B5
nom:
7853
rdg:
7851
diff:
-2
B6
nom:
7844
rdg:
7845
diff:
+1
B7
nom:
7882
rdg:
7886
diff:
+4
B8
nom:
7909
rdg:
7911
diff:
+2
C1
nom:
8134
rdg:
8127
diff:
-7
C2
nom:
8088
rdg:
8087
diff:
-1
C3
nom:
7998
rdg:
7998
diff:
+0
C4
nom:
7993
rdg:
7990
diff:
-3
Trim
Groups arranged behind each other in flight direction having more than 10
No issues were found
Group deviations
Groups that are more than 20
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found