Review measurement
2026-07-25 17:08
Ozone Zeno 2 MS (2022)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
A9
nom:
6992
rdg:
6976
diff:
-16
A10
nom:
6871
rdg:
6860
diff:
-11
A11
nom:
6806
rdg:
6801
diff:
-5
A12
nom:
6761
rdg:
6754
diff:
-7
A13
nom:
6742
rdg:
6736
diff:
-6
A14
nom:
6782
rdg:
6774
diff:
-8
B12
nom:
6769
rdg:
6764
diff:
-5
B13
nom:
6778
rdg:
6775
diff:
-3
B14
nom:
6805
rdg:
6804
diff:
-1
Trim
Groups arranged behind each other in flight direction having more than 10
This should be corrected.
Left riser
nom:
7552.63
rdg:
7553.00
diff:
0.38
nom:
7561.63
rdg:
7546.25
diff:
-15.38
Right riser
nom:
7552.63
rdg:
7554.38
diff:
1.75
nom:
7561.63
rdg:
7549.13
diff:
-12.50
Group deviations
Groups that are more than 20
The measurement baseline is the median (-6) of the deviations of all measurements from their nominal values.
No issues were found