Review measurement

2025-06-24 09:57

BGD Magic S (2019)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

c4
nom:
6391
rdg:
6392
diff:
 +1
c5
nom:
6365
rdg:
6368
diff:
 +3
c6
nom:
6366
rdg:
6372
diff:
 +6
c7
nom:
6391
rdg:
6397
diff:
 +6
d3
nom:
6517
rdg:
6509
diff:
 -8
d4
nom:
6490
rdg:
6482
diff:
 -8
d5
nom:
6491
rdg:
6486
diff:
 -5
d6
nom:
6496
rdg:
6489
diff:
 -7

Right riser

c4
nom:
6391
rdg:
6384
diff:
 -7
c5
nom:
6365
rdg:
6360
diff:
 -5
c6
nom:
6366
rdg:
6362
diff:
 -4
c7
nom:
6391
rdg:
6386
diff:
 -5
d3
nom:
6517
rdg:
6509
diff:
 -8
d4
nom:
6490
rdg:
6487
diff:
 -3
d5
nom:
6491
rdg:
6485
diff:
 -6
d6
nom:
6496
rdg:
6488
diff:
 -8

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
6269.20
rdg:
6271.60
diff:
2.40
nom:
6238.00
rdg:
6235.00
diff:
-3.00
nom:
6306.00
rdg:
6313.50
diff:
7.50

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (-1) of the deviations of all measurements from their nominal values.

No issues were found