Review measurement
2024-02-05 21:49
Niviuk Icepeak X-One 22 (2020)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
a9
nom:
7390
rdg:
7390
diff:
+0
a10
nom:
7305
rdg:
7304
diff:
-1
a11
nom:
7249
rdg:
7249
diff:
+0
a12
nom:
7261
rdg:
7264
diff:
+3
a13
nom:
7158
rdg:
7145
diff:
-13
a14
nom:
7149
rdg:
7139
diff:
-10
b9
nom:
7375
rdg:
7380
diff:
+5
c13
nom:
7167
rdg:
7149
diff:
-18
c14
nom:
7173
rdg:
7156
diff:
-17
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
No issues were found
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found