Review measurement

2026-03-05 17:09

Ozone Enzo 3 M (2017)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

B17
nom:
7703
rdg:
7700
diff:
 -3
B18
nom:
7639
rdg:
7638
diff:
 -1
B19
nom:
7621
rdg:
7620
diff:
 -1
B20
nom:
7546
rdg:
7543
diff:
 -3
B21
nom:
7550
rdg:
7546
diff:
 -4
B22
nom:
7504
rdg:
7496
diff:
 -8
B23
nom:
7512
rdg:
7501
diff:
-11

Right riser

B17
nom:
7703
rdg:
7697
diff:
 -6
B18
nom:
7639
rdg:
7632
diff:
 -7
B19
nom:
7621
rdg:
7615
diff:
 -6
B20
nom:
7546
rdg:
7542
diff:
 -4
B21
nom:
7550
rdg:
7541
diff:
 -9
B22
nom:
7504
rdg:
7490
diff:
-14
B23
nom:
7512
rdg:
7497
diff:
-15

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

This should be corrected.

Left riser

nom:
7333.00
rdg:
7303.00
diff:
-34.00

Right riser

nom:
7333.00
rdg:
7305.00
diff:
-32.00