Review measurement
2026-03-05 17:09
Ozone Enzo 3 M (2017)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
B17
nom:
7703
rdg:
7697
diff:
-6
B18
nom:
7639
rdg:
7632
diff:
-7
B19
nom:
7621
rdg:
7615
diff:
-6
B20
nom:
7546
rdg:
7542
diff:
-4
B21
nom:
7550
rdg:
7541
diff:
-9
B22
nom:
7504
rdg:
7490
diff:
-14
B23
nom:
7512
rdg:
7497
diff:
-15
Trim
Groups arranged behind each other in flight direction having more than 10
No issues were found
Group deviations
Groups that are more than 20
The measurement baseline is the median of the deviations of all measurements from their nominal values.
This should be corrected.
Left riser
nom:
7333.00
rdg:
7303.00
diff:
-34.00
Right riser
nom:
7333.00
rdg:
7305.00
diff: