2025-02-25 18:58
AirDesign Volt 4 M (2022)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
B1
nom:
7877
rdg:
7858
diff:
-19
B2
nom:
7830
rdg:
7815
diff:
-15
B3
nom:
7791
rdg:
7778
diff:
-13
B4
nom:
7809
rdg:
7794
diff:
-15
C1
nom:
8071
rdg:
8046
diff:
-25
C2
nom:
7957
rdg:
7938
diff:
-19
C3
nom:
7912
rdg:
7891
diff:
-21
C4
nom:
7947
rdg:
7926
diff:
-21
C5
nom:
7932
rdg:
7915
diff:
-17
C6
nom:
7869
rdg:
7846
diff:
-23
C7
nom:
7883
rdg:
7862
diff:
-21
C8
nom:
7968
rdg:
7946
diff:
-22
B5
nom:
7756
rdg:
7741
diff:
-15
B6
nom:
7701
rdg:
7687
diff:
-14
B7
nom:
7627
rdg:
7620
diff:
-7
B8
nom:
7634
rdg:
7625
diff:
-9
C9
nom:
7833
rdg:
7814
diff:
-19
C10
nom:
7777
rdg:
7759
diff:
-18
C11
nom:
7698
rdg:
7683
diff:
-15
C12
nom:
7701
rdg:
7687
diff:
-14
Right riser
A13
nom:
7189
rdg:
7164
diff:
-25
A14
nom:
7081
rdg:
7062
diff:
-19
A15
nom:
7062
rdg:
7041
diff:
-21
B13
nom:
7157
rdg:
7145
diff:
-12
B14
nom:
7082
rdg:
7067
diff:
-15
B15
nom:
7074
rdg:
7057
diff:
-17
C15
nom:
7193
rdg:
7172
diff:
-21
C16
nom:
7114
rdg:
7093
diff:
-21
C17
nom:
7143
rdg:
7119
diff:
-24
B1
nom:
7877
rdg:
7861
diff:
-16
B2
nom:
7830
rdg:
7814
diff:
-16
B3
nom:
7791
rdg:
7774
diff:
-17
B4
nom:
7809
rdg:
7793
diff:
-16
C1
nom:
8071
rdg:
8046
diff:
-25
C2
nom:
7957
rdg:
7937
diff:
-20
C3
nom:
7912
rdg:
7896
diff:
-16
C4
nom:
7947
rdg:
7929
diff:
-18
C5
nom:
7932
rdg:
7913
diff:
-19
C6
nom:
7869
rdg:
7851
diff:
-18
C7
nom:
7883
rdg:
7867
diff:
-16
C8
nom:
7968
rdg:
7951
diff:
-17
B5
nom:
7756
rdg:
7741
diff:
-15
B6
nom:
7701
rdg:
7689
diff:
-12
B7
nom:
7627
rdg:
7615
diff:
-12
B8
nom:
7634
rdg:
7621
diff:
-13
C9
nom:
7833
rdg:
7818
diff:
-15
C10
nom:
7777
rdg:
7760
diff:
-17
C11
nom:
7698
rdg:
7678
diff:
-20
C12
nom:
7701
rdg:
7682
diff:
-19
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
No issues were found
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found