Review measurement

2025-02-19 11:00

Ozone Zeno 2 ML (2022)

In-group deviations

Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

B5
nom:
7661
rdg:
7666
diff:
+5
B6
nom:
7519
rdg:
7525
diff:
+6
B7
nom:
7441
rdg:
7444
diff:
+3
B8
nom:
7451
rdg:
7455
diff:
+4
C5
nom:
7738
rdg:
7749
diff:
+11
C6
nom:
7595
rdg:
7607
diff:
+12
C7
nom:
7512
rdg:
7518
diff:
+6
C8
nom:
7512
rdg:
7517
diff:
+5

Right riser

B5
nom:
7661
rdg:
7672
diff:
+11
B6
nom:
7519
rdg:
7524
diff:
+5
B7
nom:
7441
rdg:
7442
diff:
+1
B8
nom:
7451
rdg:
7451
diff:
+0
C5
nom:
7738
rdg:
7747
diff:
+9
C6
nom:
7595
rdg:
7606
diff:
+11
C7
nom:
7512
rdg:
7517
diff:
+5
C8
nom:
7512
rdg:
7516
diff:
+4

Trim

Groups arranged behind each other in flight direction having more than 10 mm deviation.

This should be corrected.

Left riser

nom:
7819.88
rdg:
7813.75
diff:
-6.13
nom:
7828.38
rdg:
7833.25
diff:
+4.88

Right riser

nom:
7819.88
rdg:
7815.63
diff:
-4.25
nom:
7828.38
rdg:
7836.13
diff:
+7.75
nom:
7542.75
rdg:
7538.13
diff:
-4.63
nom:
7553.63
rdg:
7559.38
diff:
+5.75

Group deviations

Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found