Review measurement

2026-09-30 23:30

Niviuk Hook 6 26 (2022)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

c5
nom:
7072
rdg:
7062
diff:
-10
c6
nom:
6972
rdg:
6962
diff:
-10
c7
nom:
6937
rdg:
6924
diff:
-13
c8
nom:
6955
rdg:
6934
diff:
-21

Right riser

c5
nom:
7072
rdg:
7065
diff:
 -7
c6
nom:
6972
rdg:
6963
diff:
 -9
c7
nom:
6937
rdg:
6928
diff:
 -9
c8
nom:
6955
rdg:
6943
diff:
-12

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
7257.00
rdg:
7254.00
diff:
-3.00
nom:
7138.00
rdg:
7126.50
diff:
-11.50
nom:
7249.00
rdg:
7235.75
diff:
-13.25
nom:
7174.00
rdg:
7170.50
diff:
-3.50
nom:
7092.00
rdg:
7089.50
diff:
-2.50
nom:
7226.50
rdg:
7213.50
diff:
-13.00

Right riser

nom:
7257.00
rdg:
7253.50
diff:
-3.50
nom:
7138.00
rdg:
7128.50
diff:
-9.50
nom:
7249.00
rdg:
7234.25
diff:
-14.75

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (-10) of the deviations of all measurements from their nominal values.

No issues were found