Review measurement
2025-03-08 11:51
PHI Maestro Light 18 (2020)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
1B1
nom:
6727
rdg:
7254
diff:
-13
1B2
nom:
6576
rdg:
7108
diff:
-8
1B3
nom:
6588
rdg:
7116
diff:
-12
1B4
nom:
6555
rdg:
7088
diff:
-7
1B5
nom:
6506
rdg:
7044
diff:
-2
1B6
nom:
6611
rdg:
7140
diff:
-11
1C1
nom:
6761
rdg:
7285
diff:
-16
1C2
nom:
6732
rdg:
7258
diff:
-14
1C3
nom:
6620
rdg:
7153
diff:
-7
1C4
nom:
6625
rdg:
7161
diff:
-4
1C5
nom:
6657
rdg:
7191
diff:
-6
1C6
nom:
6687
rdg:
7222
diff:
-5
Right riser
1A13
nom:
5920
rdg:
6475
diff:
+15
1StA
nom:
5800
rdg:
6344
diff:
+4
1B13
nom:
5937
rdg:
6491
diff:
+14
1StB
nom:
5882
rdg:
6422
diff:
+0
1StC
nom:
5986
rdg:
6521
diff:
-5
1B1
nom:
6727
rdg:
7259
diff:
-8
1B2
nom:
6576
rdg:
7112
diff:
-4
1B3
nom:
6588
rdg:
7123
diff:
-5
1B4
nom:
6555
rdg:
7092
diff:
-3
1B5
nom:
6506
rdg:
7047
diff:
+1
1B6
nom:
6611
rdg:
7143
diff:
-8
1C1
nom:
6761
rdg:
7287
diff:
-14
1C2
nom:
6732
rdg:
7257
diff:
-15
1C3
nom:
6620
rdg:
7154
diff:
-6
1C4
nom:
6625
rdg:
7165
diff:
+0
1C5
nom:
6657
rdg:
7200
diff:
+3
1C6
nom:
6687
rdg:
7225
diff:
-2
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
No issues were found
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found