Review measurement
2025-06-20 23:05
Ozone Zeno 2 MS (2022)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
A9
        nom:
6992
rdg:
6994
diff:
 +2
A10
        nom:
6871
rdg:
6876
diff:
 +5
A11
        nom:
6806
rdg:
6808
diff:
 +2
A12
        nom:
6761
rdg:
6760
diff:
 -1
A13
        nom:
6742
rdg:
6742
diff:
 +0
A14
        nom:
6782
rdg:
6782
diff:
 +0
B12
        nom:
6769
rdg:
6767
diff:
 -2
B13
        nom:
6778
rdg:
6773
diff:
 -5
B14
        nom:
6805
rdg:
6803
diff:
 -2
Trim
                            Groups arranged behind each other in flight direction having more than 10
No issues were found
Group deviations
                                Groups that are more than 20
The measurement baseline is the median of the deviations of all measurements from their nominal values.
                            
No issues were found